Item | Specifications |
Input | Rated voltage, rated frequency | 2S: AC 1Phase 220V~240V, 50/60 HZ 2T: AC 3Phase 220V~240V, 50/60 HZ 4T: AC 3Phase 380V~440V, 50/60 HZ |
|
|
Voltage allowable fluctuation range | 2S/2T: -15%~10%, actual allowable range: AC 187V~264V 4T: -15%~10%, actual allowable range: AC 323V~484V |
|
Frequency allowable fluctuation range | -5%~5%, actual allowable range: 47.5HZ~63HZ |
Output | Output voltage (V) | AC 3phase 0~input voltage |
Maximum output frequency | 500HZ |
Basic Function | Maximum frequency | Vector control: 0~ 500Hz V/F control: 0~ 500Hz |
Carrier frequency | 0.5kHz~ 16kHz The carrier frequency can be automatically adjusted according to the load characteristics. |
Input frequency resolution | Digital setting: 0.01Hz Analog setting: maximum frequency ×0.025% |
Control mode | Sensorless Vector Control (SVC) Flux Vector Control (FVC) V/F Control |
Starting torque | G: 0.5Hz/150%(SVC); 0Hz/180%(FVC) |
P: 0.5Hz/100% |
Speed range | 1: 100 (SVC), 1: 1000 (FVC) |
Speed stability accuracy | ±0.5%(SVC), ±0.02%( FVC) |
Torque control accuracy | ±5%( FVC) |
Overload capacity | G type: 150% rated current 60s; 180% rated current 3s. P type: 120% rated current 60s; 150% rated current 3s. |
Torque boost | Automatic torque boost; Manual torque is increased by 0.1%~30.0% |
V/F curve | Three ways: Linear; Multi-point type; V/F curve of N power type (1.2 power, 1.4 power, 1.6 power, 1.8 power, 2 power) |
V/F separation | Two methods: full separation, semi-separation |
Acceleration and deceleration curve | Linear or S-curve acceleration and deceleration mode. Four kinds of acceleration and deceleration time, acceleration and deceleration time range 0.0~6500.0s |
DC braking | DC braking frequency: 0.00Hz~ maximum frequency, Brake time: 0.0s~ 36.0s, Brake action current value: 0.0%~ 100.0% |
Jog control | Jog frequency range: 0.00Hz to 50.00Hz. Jog acceleration and deceleration time 0.0s~6500.0s. |
Simple PLC/multi-speed operation | Up to 16 segment speeds are possible with built-in PLC or control terminals. |
Built-in PID | It is convenient to realize the closed-loop control system of process control. |
Automatic voltage regulation (AVR) | When the grid voltage changes, it can automatically keep the output voltage constant. |
Over-voltage, over-current and Stall control | Automatic current and voltage limit during operation to prevent frequent over-voltage trip. |
Fast current limiting function | Minimize over-current faults and protect the normal operation of the drive. |
Torque limit and control | The "excavator" feature automatically limits the torque during operation to prevent frequent over-current tripping; The closed-loop vector mode enables torque control. |
Personalized function | Excellent performance | The control of asynchronous motor and synchronous motor is realized with high performance current vector control technology. |
Non stop when instantaneous power failure | In the case of instantaneous power failure, the drive can continue to run for a short time by the load feedback energy. |
Virtual IO | Five sets of virtual DIDO, which can achieve simple logic control. |
Timing control | Timing control function: set time range 0.0Min~ 6500.0Min |
Multi-motor switching | Two sets of motor parameters can realize four motor switching control. |
Motor overheating protection | Optional motor overheat expansion card to accept motor temperature sensor input. |
Running | Command source | Operation panel given, control terminal given, serial communication port given. There are several ways to switch command given sources. |
Frequency source | 10 frequency sources: digital set, analog voltage set, analog current set, pulse set, serial port set. Can be switched in a variety of ways. |
Auxiliary frequency source | 10 auxiliary frequency sources. It can flexibly realize auxiliary frequency fine-tuning and frequency synthesis. |
Input terminal | Standard: 5 DI digital input terminals (DI1~DI5), where DI5 supports high-speed pulse input up to 100kHz (to be specified when ordering). 2 analog input terminals (AI1 to AI2, AI1 only supports 0~10V voltage input, but AI2 supports 0~10V voltage input or 4~20mA current input)
Expansion capability: 5 digital input terminals (DI6~DI10) 1 analog input terminal (AI3), supports -10, 10V voltage input and supports PT100. |
Output terminal | Standard: 1 digital output terminal (DO1) 1 relay output terminal (TA1-TB1-TC1) 1 analog output terminal (AO1), supporting 0~20mA current output.
Expansion capability: 1 analog output terminal (AO1), supporting 0~20mA current or 0~ 10V voltage output 2 relay output terminals (TA2-TB2-TC2~TA3-TB3-TC3) |
Control | RS485 communication terminal | RS485 communication interface, and support Modbus-RTU slave station communication protocol. |
Display and keyboard operation | LED display | Monitor the drive state parameters. |
Key lock and function selection | To achieve partial or total key lock, define the scope of some keys to prevent misoperation. |
Protection function | Short-circuit detection, input and output phase loss protection, overcurrent protection, overvoltage protection, undervoltage protection, overheat protection, overload protection, etc. |
Optional accessories | Brake module, IO expansion card, isolated RS485 communication card, differential input PG card, OC input PG card. |
Environment | Installation location | Indoor, free from direct sunlight, no dust, corrosive gas, flammable gas, oil mist, water vapor, dripping water or salt, etc. |
Altitude | Below 1,000 m |
Ambient temperature | -10 ° C to +40 ° C (When the ambient temperature is 40 ° C to 50 ° C, please derate by 1.5% per 1ºC increase) |
Humidity | Less than 95%RH, no condensation. |
Vibration | Less than 5.9m/(S2) (0.6g) |
Storage temperature | -20ºC~+ 60ºC |
Protection Level | IP20 |